Search results for "No detection"
showing 8 items of 8 documents
A Boron Dipyrromethene (BODIPY)-Based Cu(II) -Bipyridine Complex for Highly Selective NO Detection.
2015
[EN] A BODIPY-containing Cu-II-bipyridine complex for the simple selective fluorogenic detection of NO in air and in live cells is reported. The detection mechanism is based on NO-promoted Cu-II to Cu-I reduction, followed by demetallation of the complex, which results in the clearly enhanced emission of the boron dipyrromethene (BODIPY) unit.
Study of Large Hemispherical Photomultiplier Tubes for the ANTARES Neutrino Telescope
2005
The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a 3 dimensional matrix of 900 large area photomultiplier tubes housed in pressure resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the PMT chosen for ANTARES.
AMADEUS-The acoustic neutrino detection test system of the ANTARES deep-sea neutrino telescope
2011
The AMADEUS (ANTARES Modules for the Acoustic Detection Under the Sea) system which is described in this article aims at the investigation of techniques for acoustic detection of neutrinos in the deep sea. It is integrated into the ANTARES neutrino telescope in the Mediterranean Sea. Its acoustic sensors, installed at water depths between 2050 and 2300 m, employ piezo-electric elements for the broad-band recording of signals with frequencies ranging up to 125 kHz. The typical sensitivity of the sensors is around - 145 dB re 1 V/mu Pa (including preamplifier). Completed in May 2008, AMADEUS consists of six "acoustic clusters", each comprising six acoustic sensors that are arranged at distanc…
Inside Cover: A Boron Dipyrromethene (BODIPY)-Based CuII-Bipyridine Complex for Highly Selective NO Detection (Chem. Eur. J. 44/2015)
2015
Search for multiwavelength emission from the binary millisecond pulsar PSR J1836-2354A in the globular cluster M22
2019
We present a multi-band search for X-ray, optical and $\gamma$-ray emission of the radio binary millisecond pulsar J1836-2354A, hosted in the globular cluster M22. X-ray emission is significantly detected in two Chandra observations, performed in 2005 and 2014, at a luminosity of $\sim$2-3$\times$10$^{30}$ erg s$^{-1}$, in the 0.5-8 keV energy range. The radio and the X-ray source positions are found consistent within 1$\sigma$ error box. No detection is found in archival XMM-Newton and Swift/XRT observations, compatible with the Chandra flux level. The low statistics prevents us to assess if the X-ray source varied between the two observations. The X-ray spectrum is consistent with a power…
Background studies for acoustic neutrino detection at the South Pole
2011
The detection of acoustic signals from ultra-high energy neutrino interactions is a promising method to measure the tiny flux of cosmogenic neutrinos expected on Earth. The energy threshold for this process depends strongly on the absolute noise level in the target material. The South Pole Acoustic Test Setup (SPATS), deployed in the upper part of four boreholes of the IceCube Neutrino Observatory, has monitored the noise in Antarctic ice at the geographic South Pole for more than two years down to 500 m depth. The noise is very stable and Gaussian distributed. Lacking an in-situ calibration up to now, laboratory measurements have been used to estimate the absolute noise level in the 10 to …
Towards 14C-free liquid scintillator
2017
A series of measurements has been started where the 14C concentration is determined from several liquid scintillator samples. A dedicated setup has been designed and constructed with the aim of measuring concentrations smaller than 10−18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia, and in the new Callio Lab in the Pyhäsalmi mine, Finland. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic 14C concentration in the liquid is extremely low. In the Borexino CTF detector the concentration of 2 × 10−18 has been achieved being the lowest value ever measured. In principle, the older the oil or gas source that…
Measuring the 14C content in liquid scintillators
2016
We are going to perform a series of measurements where the 14C/12C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10−18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyh¨asalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyh¨asalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic …